http://www.su-jiao.com/ul/ UL黄卡查询
|
E67171 |
LG CHEMICAL LTD |
20 YOIDO-DONG, YONGDUNGPO-GU, SEOUL 150-721 KR |
LUPOY GP-1006F(f1), LUPOY GP-1006F(m)(#)(f1) |
Polycarbonate (PC), modified, furnished as pellets |
| Min Thk | Flame | | | RTI | RTI | RTI | Color | (mm) | Class | HWI | HAI | Elec | Imp | Str | ALL | 1.5 | V-0 | 3 | 0 | 120 | 110 | 120 | | 2.5 | V-0,5VA | - | - | 120 | 110 | 120 | | 3.0 | V-0,5VA | 2 | 0 | 120 | 110 | 120 |
Comparative Tracking Index (CTI): | 2 | Inclined Plane Tracking (IPT): | - | Dielectric Strength (kV/mm): | - | Volume Resistivity (10x ohm-cm) : | - | High-Voltage Arc Tracking Rate (HVTR): | 3 | High Volt, Low Current Arc Resis (D495): | 7 | Dimensional Stability (%): | - | | |
(#) - | May be followed by optional suffix letter from A-Z incl., except F, and except Grades AF302G, HT700B, XR401B, LI912A, AF303G, AF303S, XR404T, XR407D, XR407E, HF380X. | (f1) - | Suitable for outdoor use with respect to exposure to Ultraviolet Light, Water Exposure and Immersion in accordance with UL 746C. | (m) - | May be followed by 1 or 2 suffix letters from A-Z incl., except F, FF, FH. |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date:
1997-12-11
Last Revised:
2006-01-06 |
手机:13424755533 |
|
| | | Thickness | | Test Name | Test Method | Units | Tested (mm) | Value | Flammability | IEC 60695-11-10, IEC 60695-11-20 | Class (color) | 1.5 | V-0 (ALL) | | | | 2.5 | V-0,5VA (ALL) | | | | 3.0 | V-0,5VA (ALL) | Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | - | - | Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | - | - | IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - | IEC Ball Pressure | IEC 60695-10-2 | C | - | - | ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - | ISO Tensile Strength | ISO 527-2 | MPa | - | - | ISO Flexural Strength | ISO 178 | MPa | - | - | ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - | ISO Izod Impact | ISO 180 | kJ/m2 | - | - | ISO Charpy Impact | ISO 179-2 | kJ/m2 | - | - |
|