AMERICAS - RESIN, 1 PLASTICS AVE, PITTSFIELD MA 01201
203(f1), 203R(f1), 243(f1), 243R(f1), V2222(f1)
Polycarbonate (PC), "Lexan", furnished as pellets
Min Thk
Flame
RTI
RTI
RTI
Color
(mm)
Class
HWI
HAI
Elec
Imp
Str
ALL
0.75
V-2
-
-
120
120
120
1.5
V-2
3
2
130
125
125
3.0
V-2
2
1
130
130
130
6.0
V-0
2
2
130
130
130
Comparative Tracking Index (CTI):
2
Inclined Plane Tracking (IPT):
-
Dielectric Strength (kV/mm):
-
Volume Resistivity (10x ohm-cm) :
-
High-Voltage Arc Tracking Rate (HVTR):
2
High Volt, Low Current Arc Resis (D495):
-
Dimensional Stability (%):
0
(f1) -
Suitable for outdoor use with respect to exposure to Ultraviolet Light, Water Exposure and Immersion in accordance with UL 746C.
NOTE -
Material designation may be followed by a color nomenclature consisting of either an alpha/numeric or numeric/alpha combination.
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL.