www.su-jiao.com/ul/ UL黄卡
|
E67171 |
LG CHEMICAL LTD |
20 YOIDO-DONG, YONGDUNGPO-GU, SEOUL 150-721 KR |
AF342(#), AF342NS |
Acrylonitrile Butadiene Styrene (ABS), furnished as pellets |
| Min Thk | Flame | | | RTI | RTI | RTI | Color | (mm) | Class | HWI | HAI | Elec | Imp | Str | ALL | 1.5 | V-0 | 4 | 0 | 60 | 60 | 60 | | 2.0 | V-0, 5VB | 4 | 0 | 60 | 60 | 60 | | 2.5 | V-0, 5VB | 4 | 0 | 60 | 60 | 60 | | 3.0 | V-0, 5VB | 1 | 0 | 60 | 60 | 60 | GY | 3.0 | V-0, RP35 | 1 | 0 | 60 | 60 | 60 |
Comparative Tracking Index (CTI): | 1 | Inclined Plane Tracking (IPT): | - | Dielectric Strength (kV/mm): | 36 | Volume Resistivity (10x ohm-cm) : | 12 | High-Voltage Arc Tracking Rate (HVTR): | 4 | High Volt, Low Current Arc Resis (D495): | 7 | Dimensional Stability (%): | 0.0 | | |
(#) - | May be followed by optional suffix letter from A-Z incl., except F, and except Grades AF302G, HT700B, XR401B, LI912A, AF303G, AF303S, XR404T, XR407D, XR407E, HF380X. |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date:
1985-11-19
Last Revised:
2013-06-11 |
联系人:赵经理 |
|
| | | Thickness | | Test Name | Test Method | Units | Tested (mm) | Value | Flammability | IEC 60695-11-10, IEC 60695-11-20 | Class (color) | 1.5 | V-0 (ALL) | | | | 2.0 | V-0, 5VB (ALL) | | | | 2.5 | V-0, 5VB (ALL) | | | | 3.0 | V-0, 5VB (ALL) | | | | 3.0 | V-0, RP35 (GY) | Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | - | - | Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | - | - | IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - | IEC Ball Pressure | IEC 60695-10-2 | C | - | - | ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - | ISO Tensile Strength | ISO 527-2 | MPa | - | - | ISO Flexural Strength | ISO 178 | MPa | - | - | ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - | ISO Izod Impact | ISO 180 | kJ/m2 | - | - | ISO Charpy Impact | ISO 179-2 | kJ/m2 | - | - |
|