UL黄卡 www.su-jiao.com/ul/
|
E121562 |
SABIC INNOVATIVE PLASTICS US L L C |
AMERICAS - RESIN, 1 PLASTICS AVE, PITTSFIELD MA 01201 |
ZK1(f2)(c), FR15U(f2)(c) |
Acrylonitrile Butadiene Styrene (ABS), "Cycolac", furnished as pellets |
| Min Thk | Flame | | | RTI | RTI | RTI | Color | (mm) | Class | HWI | HAI | Elec | Imp | Str | BL, GN | 1.5 | V-0, RP75 | 3 | 0 | 60 | 60 | 60 | | 2.0 | V-0, 5VB | - | - | 60 | 60 | 60 | | 2.8 | V-0, 5VA | - | - | 60 | 60 | 60 | | 3.0 | V-0, 5VA | 1 | 0 | 60 | 60 | 60 | | 6.0 | V-0, 5VA | 0 | 0 | 60 | 60 | 60 |
Comparative Tracking Index (CTI): | 1 | Inclined Plane Tracking (IPT): | - | Dielectric Strength (kV/mm): | 20 | Volume Resistivity (10x ohm-cm) : | 14 | High-Voltage Arc Tracking Rate (HVTR): | 4 | High Volt, Low Current Arc Resis (D495): | 6 | Dimensional Stability (%): | 0.05 | | |
(c) - | ASTM E162 (Radiant Panel) For All colors except WT, 2.0 mm - 3.2 mm - Flame Spread Index less than 100; Sustained Flaming: 12 in.; Dripping: None. WT color, 2.0 mm - 3.2 mm - Flame Spread Index less than 50; Sustained Flaming: 12 in.; Dripping: None. | (f2) - | Subjected to one or more of the following tests: Ultraviolet Light, Water Exposure or Immersion in accordance with UL 746C, where the acceptability for outdoor use is to be determined by UL. | NOTE - | Material designation may be followed by a color nomenclature consisting of either an alpha/numeric or numeric/alpha combination. |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date:
1972-04-14
Last Revised:
2012-07-06 |
联系电话:13424755533 |
|
| | | Thickness | | Test Name | Test Method | Units | Tested (mm) | Value | Flammability | IEC 60695-11-10, IEC 60695-11-20 | Class (color) | 1.5 | V-0, RP75 (BL, GN) | | | | 2.0 | V-0, 5VB (BL, GN) | | | | 2.8 | V-0, 5VA (BL, GN) | | | | 3.0 | V-0, 5VA (BL, GN) | | | | 6.0 | V-0, 5VA (BL, GN) | Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | 1.5 | 960 | | | | 2.0 | 960 | | | | 2.8 | 960 | | | | 3.0 | 960 | | | | 6.0 | 960 | Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | 1.5 | 700 | | | | 2.0 | 700 | | | | 2.8 | 700 | | | | 3.0 | 700 | | | | 6.0 | 700 | IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - | IEC Ball Pressure | IEC 60695-10-2 | C | - | - | ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - | ISO Tensile Strength | ISO 527-2 | MPa | - | - | ISO Flexural Strength | ISO 178 | MPa | - | - | ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - | ISO Izod Impact | ISO 180 | kJ/m2 | - | - | ISO Charpy Impact | ISO 179-2 | kJ/m2 | - | - |
|