- 密度 [g/cm3]: 1.14
- 吸水率 [%]: 0.2
- 缺口冲击强度: 6.5
- 弯曲模量 [MPa]: 2.70
Physical Properties | Metric | English | Comments | ||
---|---|---|---|---|---|
Density | 1.14 g/cc | 0.0412 lb/in³ | Test Method A; ISO 1183:1987 | ||
Water Absorption | 0.20 % @Temperature 23.0 °C, Time 86400 sec | 0.20 % @Temperature 73.4 °F, Time 24.0 hour | Immersion; ISO 62:1999 (modified) | ||
Water Absorption at Saturation | 5.0 % | 5.0 % | ISO 62:1999 | ||
Mechanical Properties | Metric | English | Comments | ||
Hardness, Shore D | 80 | 80 | ISO 868:2003 | ||
Tensile Strength at Break | 75.0 MPa | 10900 psi | Sample Type 1B, 50mm/min; ISO 527-1/2:1993 | ||
Elongation at Break | >= 30 % | >= 30 % | Sample Type 1B, 50 mm/min; ISO 527-1/2:1993 | ||
Modulus of Elasticity | 3.70 GPa | 537 ksi | Sample Type 1B, 50 mm/min; ISO 527-1/2:1993 | ||
Flexural Strength | 95.0 MPa | 13800 psi | 1.5 mm/min; ISO 178:2001 | ||
Flexural Modulus | 2.70 GPa | 392 ksi | 1.5 mm/min; ISO 178:2001 | ||
Compressive Strength | 90.0 MPa | 13100 psi | Sample Type B, 5 mm/min; ISO 604:2002 | ||
Compressive Modulus | 2.00 GPa | 290 ksi | Sample Type A, 1 mm/min; ISO 604:2002 | ||
Izod Impact, Notched (ISO) | 6.50 kJ/m² | 3.09 ft-lb/in² | Sample Type A; ISO 180:2000 | ||
Electrical Properties | Metric | English | Comments | ||
Volume Resistivity | 1.00e+15 ohm-cm | 1.00e+15 ohm-cm | IEC 60093:1980-01 | ||
Surface Resistance | 1.00e+12 ohm | 1.00e+12 ohm | IEC 60093:1980-01 | ||
Dielectric Constant | 3.7 @Frequency 1.00e+6 Hz | 3.7 @Frequency 1.00e+6 Hz | IEC 60250:1969-01 | ||
4.0 @Frequency 100 Hz | 4.0 @Frequency 100 Hz | IEC 60250:1969-01 | |||
Dielectric Strength | 25.0 kV/mm | 635 kV/in | IEC 60243-1:1998-01 | ||
Comparative Tracking Index | 600 V | 600 V | IEC 60112:2003-01 | ||
Thermal Properties | Metric | English | Comments | ||
CTE, linear | 85.0 µm/m-°C @Temperature 23.0 - 55.0 °C | 47.2 µin/in-°F @Temperature 73.4 - 131 °F | ISO 11359-2:1999 | ||
Melting Point | 215 °C | 419 °F | |||
Maximum Service Temperature, Air | 100 °C | 212 °F | Continuous | ||
160 °C | 320 °F | Intermittent | |||
Minimum Service Temperature, Air | -100 °C | -148 °F | Intermittent | ||
-40.0 °C | -40.0 °F | Continuous | |||
Flammability, UL94 | HB | HB | IEC 60695-11-10:2003-08 | ||
Descriptive Properties | |||||
Color | Natural, Yellow |