Availability
|
|
|||
Features
|
|
|||
Uses
|
|
|||
Forms
|
|
Physical | Dry | Conditioned |
Unit
|
Test Method
|
Density
|
1.46
|
--
|
g/cm³
|
ISO 1183/A |
Hardness | Dry | Conditioned |
Unit
|
Test Method
|
Shore Hardness (Shore D)
|
88
|
84
|
|
ISO 868 |
Mechanical | Dry | Conditioned |
Unit
|
Test Method
|
Tensile Stress (Break)
|
85.0
|
60.0
|
MPa
|
ISO 527-2 |
Tensile Strain (Break)
|
5.0
|
25
|
%
|
ISO 527-2 |
Flexural Modulus
|
5000
|
1600
|
MPa
|
ISO 178 |
Impact | Dry | Conditioned |
Unit
|
Test Method
|
Charpy Notched Impact Strength
|
5.0
|
9.0
|
kJ/m²
|
ISO 179/1eA |
Charpy Unnotched Impact Strength
|
30 kJ/m²
|
No Break
|
|
ISO 179/1eU |
Notched Izod Impact Strength
|
5.0
|
9.0
|
kJ/m²
|
ISO 180/1A |
Thermal | Dry | Conditioned |
Unit
|
Test Method
|
Heat Deflection Temperature (1.8 MPa, Unannealed)
|
140
|
--
|
°C
|
ISO 75-2/Af |
Melting Temperature (DSC)
|
260
|
--
|
°C
|
ISO 3146 |
CLTE - Flow
|
0.000055
|
--
|
cm/cm/°C
|
ASTM E831 |
Electrical | Dry | Conditioned |
Unit
|
Test Method
|
Volume Resistivity
|
1.0E+15
|
1.0E+11
|
ohm·cm
|
IEC 60093 |
Electric Strength
|
30
|
25
|
kV/mm
|
IEC 60243-1 |
Comparative Tracking Index (Solution A)
|
550
|
--
|
V
|
IEC 60112 |