Availability
|
|
|||
Filler / Reinforcement
|
|
|||
Additive
|
|
|||
Features
|
|
|||
RoHS Compliance
|
|
|||
Forms
|
|
|||
Multi-Point Data
|
|
Physical | Dry | Conditioned |
Unit
|
Test Method
|
Density
|
1.49
|
--
|
g/cm³
|
ISO 1183 |
Molding Shrinkage
|
ISO 294-4 | |||
Across Flow
|
0.40
|
--
|
%
|
|
Flow
|
0.40
|
--
|
%
|
|
Water Absorption
|
ISO 62 | |||
Saturation, 23°C
|
5.3
|
--
|
%
|
|
Equilibrium, 23°C, 50% RH
|
1.4
|
--
|
%
|
Mechanical | Dry | Conditioned |
Unit
|
Test Method
|
Tensile Modulus
|
8500
|
4400
|
MPa
|
ISO 527-2 |
Tensile Stress (Break)
|
75.0
|
45.0
|
MPa
|
ISO 527-2 |
Tensile Strain (Break)
|
2.0
|
11
|
%
|
ISO 527-2 |
Impact | Dry | Conditioned |
Unit
|
Test Method
|
Charpy Notched Impact Strength
|
ISO 179/1eA | |||
-30°C
|
3.0
|
3.0
|
kJ/m²
|
|
23°C
|
5.0
|
10
|
kJ/m²
|
|
Charpy Unnotched Impact Strength
|
ISO 179/1eU | |||
-30°C
|
25
|
25
|
kJ/m²
|
|
23°C
|
30
|
40
|
kJ/m²
|
Thermal | Dry | Conditioned |
Unit
|
Test Method
|
Heat Deflection Temperature
|
||||
0.45 MPa, Unannealed
|
245
|
--
|
°C
|
ISO 75-2/B |
1.8 MPa, Unannealed
|
200
|
--
|
°C
|
ISO 75-2/A |
Melting Temperature 3
|
260
|
--
|
°C
|
ISO 11357-3 |
CLTE
|
ISO 11359-2 | |||
Flow
|
0.000040
|
--
|
cm/cm/°C
|
|
Transverse
|
0.000040
|
--
|
cm/cm/°C
|
Electrical | Dry | Conditioned |
Unit
|
Test Method
|
Surface Resistivity
|
--
|
1.0E+13
|
ohm
|
IEC 60093 |
Volume Resistivity
|
1.0E+14
|
1.0E+12
|
ohm·cm
|
IEC 60093 |
Electric Strength
|
35
|
30
|
kV/mm
|
IEC 60243-1 |
Relative Permittivity
|
IEC 60250 | |||
100 Hz
|
3.80
|
10.0
|
|
|
1 MHz
|
3.50
|
4.00
|
|
|
Dissipation Factor
|
IEC 60250 | |||
100 Hz
|
0.010
|
0.30
|
|
|
1 MHz
|
0.011
|
0.10
|
|
|
Comparative Tracking Index
|
600
|
600
|
V
|
IEC 60112 |
Flammability | Dry | Conditioned |
Unit
|
Test Method
|
Flammability Classification
|
IEC 60695-11-10, -20 | |||
0.710 mm
|
HB
|
--
|
|
|
1.50 mm
|
HB
|
--
|